CENTRA 200

CENTRA® R200

Complete water purification, storage, control and distribution.

Features
  • Compact design provides more flexible installation options for new buildings and refurbishments. The CENTRA’s small footprint means that it can be placed closer to the laboratory, avoiding the negative cost and design implications of long pipework loops.
  • Reliable, continual supply of pure water using unique access controls, leak detection systems and full AV alarms with optional building management system (BMS) connectivity.
  • Optimized inorganic water quality through the use of in-line purification technologies. Recirculated water is UV treated, filtered and (if fitted) can be improved through deionization
  • 200 l/hr of purified water available at up to 30 l/min from a distribution loop. A wide range of water purities are possible from RO permeate up to 18.2 MΩ-cm Type I purity
  • Low microbial counts achieved through vent filtration, spray-ball water distribution and smooth internal surface in the reservoir combined with UV oxidation and 0.2 μm filtration in the loop

Centralized Purification and Distribution Systems

CENTRA has revolutionized the way that large volumes of pure water are produced, stored and distributed. The CENTRA R-200 is a complete water purification, storage, control, and distribution system providing Type I (Ultrapure), Type II and Type III pure water. Featuring 200 liters per hour reverse osmosis module and 0.2 µm filter.

CENTRA R200 Flow

"We had been spending a lot on consumables from point of use systems across our laboratory. It took our time to replace consumables regularly too which impacted on our workflow. By having a centralised system we removed all of those issues, it has made our lab so much more productive."

FAITH BLOCK, CHEMISTRY GRADUATE
ALTO LABS

Tech Specs

PRODUCT SPECIFICATIONSCENTRA R200 HFVCENTRA R200CENTRA R200 HFR
Dispense flowrateUp to 38 l/minup to 18 l/minup to 38 l/min
Inorganics (resistivity at 25°C)Up to 18.2 MΩ.cm *Up to 18.2 MΩ.cm *Up to 18.2 MΩ.cm *
Organics (TOC)<10 ppb **<10 ppb **<10 ppb **
Bacteria<5 CFU/ml **<5 CFU/ml **<5 CFU/ml **
Particles0.2 μm filtration0.2 μm filtration0.2 μm filtration
Daily usage (max)Up to 6000 l/dayUp to 6000 l/dayUp to 6000 l/day
Delivery flow rateUp to 38 l/minup to 18 l/minup to 38 l/min
PRODUCT SPECIFICATIONSCENTRA R200 HFVCENTRA R200CENTRA R200 HFR
Dispense flowrateUp to 38 l/minup to 18 l/minup to 38 l/min
Inorganics (resistivity at 25°C)Up to 18.2 MΩ.cm *Up to 18.2 MΩ.cm *Up to 18.2 MΩ.cm *
Organics (TOC)<10 ppb **<10 ppb **<10 ppb **
Bacteria<5 CFU/ml **<5 CFU/ml **<5 CFU/ml **
Particles0.2 μm filtration0.2 μm filtration0.2 μm filtration
Daily usage (max)Up to 6000 l/dayUp to 6000 l/dayUp to 6000 l/day
Delivery flow rateUp to 38 l/minup to 18 l/minup to 38 l/min

* Ion-exchange cylinder installed (Nuclear or Hypex grade).

** System to be installed following ELGA LabWater installation guidelines and regularly sanitized.

Consumables

Composite Vent Filter
Impact of Overuse

Increase in airborne contaminants and potential recontamination of purified water

Composite Vent Filter
Part Number
LC173
Life expectancy
12 months
Impurities Removed
Reverse Osmosis
Impact of Overuse

High levels of organics and inorganics remain in the water reducing the functional life of the DI pack

Reverse Osmosis Module
Part Number
LC161
Life expectancy
24-36 months
Ultra-micron filter
Impact of Overuse

Reduced flow-rates and bacterial specification will not be maintained

Ultra-micron filter
Part Number
LC160
Life expectancy
14 months
Pre-treatment Pack
Impact of Overuse

Chlorine, chloramine and organics remain, increasing the burden on downstream consumables which will need more frequent and expensive changes

Pre-treatment
Part Number
LC159
Life expectancy
6 months
UV Light
Impact of Overuse

Uncontrolled bacterial contamination and TOC levels are not reduced

UV Light
Part Number
LC158
Life expectancy
12-18 months
Composite Vent Filter
Impact of Overuse

Increase in airborne contaminants and potential recontamination of purified water

Composite Vent Filter
Part Number
LC156
Life expectancy
12 months
Impurities Removed
Composite Vent Filter
Impact of Overuse

Increase in airborne contaminants and potential recontamination of purified water

Composite Vent Filter
Part Number
LC173
Life expectancy
12 months
Impurities Removed
Reverse Osmosis
Impact of Overuse

High levels of organics and inorganics remain in the water reducing the functional life of the DI pack

Reverse Osmosis Module
Part Number
LC161
Life expectancy
24-36 months
Ultra-micron filter
Impact of Overuse

Reduced flow-rates and bacterial specification will not be maintained

Ultra-micron filter
Part Number
LC160
Life expectancy
14 months
Pre-treatment Pack
Impact of Overuse

Chlorine, chloramine and organics remain, increasing the burden on downstream consumables which will need more frequent and expensive changes

Pre-treatment
Part Number
LC159
Life expectancy
6 months
UV Light
Impact of Overuse

Uncontrolled bacterial contamination and TOC levels are not reduced

UV Light
Part Number
LC158
Life expectancy
12-18 months
Composite Vent Filter
Impact of Overuse

Increase in airborne contaminants and potential recontamination of purified water

Composite Vent Filter
Part Number
LC156
Life expectancy
12 months
Impurities Removed

faqs

What is the CENTRA R200?

The CENTRA R200 is a purification system designed to feed a whole building from a plant room. It provides RO to type 1 ultra pure water dependent upon the consumables included. Its 200m loop can cover multiple floors or multiple laboratories on a single floor to provide a truly centralised solution. The CENTRA saves space in comparison to competitive products by having an integral 350L reservoir to significantly reduce its footprint.

What if I need more than 200 L per hour?

If you have the need for higher volumes of water ELGA's distribution network can create a duplex installation to meet your needs, this has the added benefit of providing redundancy to ensure you still have water whilst one system is being serviced.

How does the CENTRA R200 get type 1 water?

The CENTRA uses an SDI cylinder with a mixed bed resin to remove Ionic content and produce type 1 water.

 

WHITEPAPER

Protecting Clinical Output from Water Risks Thumbnail

Protecting Clinical Output from Water Risks

When lives are at stake, there is no margin for error. Your clinical analyser must receive a constant and reliable supply of CLRW* water, regardless of the quality of the feedwater available. Download our whitepaper to learn more.