The compact solution for distribution loops
The MEDICA-R200 feeds large automated diagnostic analyzers with a guaranteed high output and bacterial specification. This system provides CLRW standard (formally CLSI Type 1) pure water to multiple clinical analyzers across several laboratories making it highly flexible and reliable.
MEDICA R-200 features a unique, award-winning design incorporating a very high output water purification system, large 350-liter storage reservoir and distribution loop pump. By integrating the reservoir and water purification components into one compact system the MEDICA R-200 is very cost-effective to install and maintain on a loop system.
Tech Specs
PRODUCT SPECIFICATIONS | MEDICA R200 |
---|---|
Inorganics (resistivity at 25°C) | >10 MΩ.cm * |
Organics (TOC) | <30 ppb * |
Bacteria | <10 CFU/ml ** |
Particles | 0.2 μm filter |
Silica | <0.05 mg/l |
Delivery flow rate | 18-21 l/min |
PRODUCT SPECIFICATIONS | MEDICA R200 |
---|---|
Inorganics (resistivity at 25°C) | >10 MΩ.cm * |
Organics (TOC) | <30 ppb * |
Bacteria | <10 CFU/ml ** |
Particles | 0.2 μm filter |
Silica | <0.05 mg/l |
Delivery flow rate | 18-21 l/min |
* With Ion-exchange cylinder installed (Nuclear or Hypex grade resin)
** Subject to correct operating and maintenance procedures
Consumables
FAQs
- What is the MEDICA product range?
The MEDICA product range is specifically targeted at the Clinical diagnostics market. The MEDICA will either directly feed (analysers which require a direct feed) or fill via a dispense gun the analyser with water that meets the recommendations of the Clinical Laboratory Standards Institute (CLSI).
- How often do I need to change my consumables?
Consumables life depends entirely on the quality and volume of water being fed into the MEDICA product. Higher volumes and lower quality water will increase consumables usage.
- What feedwater is required?
Normally potable water is sufficient as feedwater. However, the quality of potable water can vary between countries and regions. Feed water specifications can be found in the operators manual and the data sheet of the product. It is important that if the feedwater specification is exceeded suitable pre-treatment be installed to bring the feedwater within specifications.
- What is the MEDICA R200?
The MEDICA R200 is a water purification system designed to feed the highest throughput analysers requiring up to 200L/hr of water. It has an integral 350L reservoir to provide significant stored water.
- I don't have much space in my laboratory, where can I install the MEDICA R200?
The MEDICA R200 can be installed in a plant room as it is possible to run a 200m loop from the product to the analyser. Loop installation and design will be handled by your local ELGA distributor.