Chorus 1

PURELAB® Chorus 1

The ultimate in water purity for life sciences and analytical applications.

Features
  • Advanced PureSure Deionization Eliminates trace ions that leach into your water and provides advanced warning to change the purification packs.
  • Fully Recirculating Ensuring microbial purity and guaranteeing pure water at the point-of-use.
  • Real-time TOC Monitoring Provides complete confidence in organic purity.
  • Integrated Filtration Ultrafiltration or microfiltration filters out endotoxins, proteins, nucleases, and particulates.
  • Full Spectrum UV Treatment
  • Data Capture Data capture via USB for system performance validation and software updates.

Life Science | Analytical Research | General Science

When you require the ultimate in water purity, PURELAB Chorus 1 provides the perfect solution. Consistently delivering water purity of 18.2 MΩ.cm (Type I+/I) and underpinned by the advanced PureSure® deionization system, the PURELAB Chorus 1 enables you to focus on attaining accurate results while ensuring an uninterrupted workflow.

"Chorus 1 has a Very Sleek Look with Excellent Performance! Simple to use/operate. Produces excellent water quality. We have ours set up after a DI system so we get a very long life from the purification packs. Sleek look and feel. Digital readouts let you know what's going on. Has a great feature which allows for set volume dispensing, if needed."

CHRIS CARSON, SELECT SCIENCE REVIEWER
PLUM CREEK WATER RECLAMATION AUTHORITY

Tech Specs

PRODUCT SPECIFICATIONS
LIFE SCIENCES
ANALYTICAL RESEARCH
GENERAL SCIENCES
Dispense flowrateUp to 2.0 l/min ***Up to 2.0 l/min***Up to 2.0 l/min ***
Inorganics (resistivity at 25°C)18.2 MΩ.cm18.2 MΩ.cm18.2 MΩ.cm
Organics (TOC)1-3 ppb *1-3 ppb*3-10 ppb *
Bacteria<0.001 CFU/ml **<0.001 CFU/ml**<0.001 CFU/ml **
Bacterial endotoxin<0.001 EU/ml<0.001 EU/ml**<0.001 EU/ml **
pHEffectively neutralEffectively neutralEffectively neutral
Particles<0.01µm<0.05 μm0.2 μm **
DNase<5 pg/ml<5 pg/ml<5 pg/ml
RNase<1 pg/ml<1 pg/ml<1 pg/ml
Daily usage (max)120 l/day120 l/day120 l/day
Daily usage (min)1 l/day1 l/day1 l/day
Delivery flow rateUp to 2.0 l/minUp to 2.0 l/minUp to 2.0 l/min
PRODUCT SPECIFICATIONS
LIFE SCIENCES
ANALYTICAL RESEARCH
GENERAL SCIENCES
Dispense flowrateUp to 2.0 l/min ***Up to 2.0 l/min***Up to 2.0 l/min ***
Inorganics (resistivity at 25°C)18.2 MΩ.cm18.2 MΩ.cm18.2 MΩ.cm
Organics (TOC)1-3 ppb *1-3 ppb*3-10 ppb *
Bacteria<0.001 CFU/ml **<0.001 CFU/ml**<0.001 CFU/ml **
Bacterial endotoxin<0.001 EU/ml<0.001 EU/ml**<0.001 EU/ml **
pHEffectively neutralEffectively neutralEffectively neutral
Particles<0.01µm<0.05 μm0.2 μm **
DNase<5 pg/ml<5 pg/ml<5 pg/ml
RNase<1 pg/ml<1 pg/ml<1 pg/ml
Daily usage (max)120 l/day120 l/day120 l/day
Daily usage (min)1 l/day1 l/day1 l/day
Delivery flow rateUp to 2.0 l/minUp to 2.0 l/minUp to 2.0 l/min

* Dependant on feed water - recommended feed <50 ppb TOC  ** With POU filter fitted   *** When connected to Halo, Advanced or flexible

Consumables

Accessories

Ultra filter
Impact of Overuse

Bacterial and endotoxin specification wil lnot be maintained. Reduced flow rate.

Ultra filter
Part Number
LC151
Life expectancy
24 months
Impurities Removed
POU Filter
Impact of Overuse

Potential recontamination of purified water and reduced flow rates

Point-of-use Filter
Part Number
LC145
Life expectancy
3 months
UV Light
Impact of Overuse

Uncontrolled bacterial contamination and TOC levels are not reduced

UV Light
Part Number
LC210
Life expectancy
12-18 months
Impurities Removed
DI Pack
Impact of Overuse

Weakly bound ions are released back into the water reducing resistivity

DI Pack
Part Number
LC232, LC244, LC245 or LC246
Life expectancy
12 months
Ultra filter
Impact of Overuse

Bacterial and endotoxin specification wil lnot be maintained. Reduced flow rate.

Ultra filter
Part Number
LC151
Life expectancy
24 months
Impurities Removed
POU Filter
Impact of Overuse

Potential recontamination of purified water and reduced flow rates

Point-of-use Filter
Part Number
LC145
Life expectancy
3 months
UV Light
Impact of Overuse

Uncontrolled bacterial contamination and TOC levels are not reduced

UV Light
Part Number
LC210
Life expectancy
12-18 months
Impurities Removed
DI Pack
Impact of Overuse

Weakly bound ions are released back into the water reducing resistivity

DI Pack
Part Number
LC232, LC244, LC245 or LC246
Life expectancy
12 months

FAQs

What is a PURELAB Chorus 1 range?

The PURELAB Chorus 1 range is designed for highly sensitive applications in analytical research, life science and general science . The range incorporates our PureSure technology which is designed to guarantee water purity at all times as well as ensures minimal running costs.

What type of water is dispensed from a PURELAB Chorus 1 system?

The PURELAB Chorus 1 range dispenses Type I (ultrapure) from a pre-treated source.

What type of applications are suitable for the water dispensed from a PURELAB Chorus 1 system?

PURELAB Chorus 1 range is suitable for applications including ultra trace analyses, mass spectrometry, molecular biology, electrochemistry, atomic spectroscopy, liquid chromatography, gas chromatography, immunochemistry, cell culture, and qualitative analysis.

What are the benefits of the PURELAB Chorus 1 range?

Besides dispensing water for applications requiring the ultimate in water purity, the PURELAB Chorus 1 range offers real-time TOC monitoring which is calculated every 2-3 seconds to give a real time TOC reading for maximum assurance; it offers water quality monitoring up to the point of dispense to help ensure valuable parameters are provided at all times; it offers a variety of purification packs to help maintain optimum water purity and a range of dispensing solutions to suit different applications and budgets..

How many product variants are available?

The PURELAB Chorus 1 range has three variants; analytical research; life science and general science.

What storage reservoirs are available with the PURELAB Chorus 1 range?

The PURELAB Chorus 1 range offers customers a choice of 4 reservoir sizes; 15l, 30l, 60l and 100l.

 

WHITEPAPER

5 steps to a biosafe lab

 

5 Steps to a BioSafe Lab

Fill in the form below to download our whitepaper which will take you through some of the key criteria to consider when designing, building and using biosafety laboratories at different levels, whether starting from scratch, or retrofitting your lab to be at a higher biosafety level than currently.